Specifications Of Detached Factory Type B
|
(A) BUILDING
|
Piling: |
Layout to be based on Consultant's Design. |
Standard piles (150mm x 150mm, square cross-section). |
Sub-Structure Works: |
Pilecap, stump, ground beam and non-suspended ground slab (floor loading of 15kN/m2) in reinforced concrete. |
Frame & Roof Structure: |
Steel portal frame. |
Roofing: |
0.40mm TCT (Total Coated Thickness) GI Colourbond metal roofing sheet c/w insulation and metal fascia cladding. |
Walls: |
Production Area
|
115mm thick clay brick wall c/w plastering & painting on both sides (from ground level to 3m height), Colourbond 0.36mm TCT metal wall cladding with transparent sheet (above 3m height). |
Washrooms - 300mm x 300mm ceramic tiles (from ground level to 2100mm height). |
Office
|
Full-height 115mm thick clay brick wall c/w plastering & painting on both sides.
|
Washrooms - 300mm x 300mm ceramic tiles (from ground level to 2100mm height). |
Floor Finishes: |
Production Area- Non-metallic floor hardener (4kg/m2).
|
First floor office - Screeded concrete.
|
Ground floor lobby -600mm x 600mm homogeneous polished tiles.
|
Washrooms -300mm x 300mm ceramic tiles. |
Doors & Windows: |
Production Area
|
Doors - Mild steel door c/w mild steel frame.
|
Windows – Natural anodized aluminium frame c/w reflective glass. |
Office Area
|
Doors - Fire-rated (1hr) timber door c/w aluminium frame, frameless tempered glass door (for lobby). |
Windows – Natural anodized aluminium frame c/w reflective glass. |
Ceiling Finishes: |
Ground floor lobby - Gypsum board plaster ceiling.
|
First floor - 2' X 4' pinhole gypsum board c/w aluminium frame. |
(B) EXTERNAL WORKS SPECIFICATIONS
|
Drainage: |
450mm / 600mm diameter conceal pipe. |
Driveway/External Roads: |
125mm thick reinforced concrete with 200mm thick crusher run foundation. |
Fencing: |
Front of building: 2000mm high brick wall for signage, 2000mm high GI fencing for remainder. |
2000mm high PVC coated chain link fencing on left, right and rear sides of building |
Main Gate: |
1 no. 9 meter mild steel sliding gate.
|
Landscaping Works: |
To local authorities requirement. |
(C) MECHANICAL AND ELECTRICAL SYSTEMS
|
Fire Fighting: |
a. Hose reel system.
|
b. Fire alarm system c/w break glass units.
|
c. "Keluar" sign and emergency lights. |
Electrical: |
a. 150A LV Main Switch Board.
|
b. Basic lighting points for Production Area.
|
c. Basic lighting points for Office Area.
|
d. Lightning protection system.
|
e. Standard power sockets for Office and Production Area. |
Plumbing: |
a. HDPE piping from external SAJ domestic water meter to storage tank.
|
b. Cold water storage tank and distribution piping.
|
c. All materials are SIRIM-compliant and have been approved by local authorities. |
Sanitary: |
a. All external manholes connected via Vitrified Clay Piping (VCP).
|
b. UPVC piping from building to external manhole.
|
c. All materials are SIRIM-compliant and have been approved by local authorities.
|
d. Connection from building to IWK sewage treatment plant. |